Concise Motion Systems
Home  | About Us  | Products  | Brands  | Applications  | Repairs  | Parts  | Contact Us  | Search    
 
innovative compact motion solutions
 
   
Linear Actuators
Rotary Actuators
Gearmotors
PushPull Chain
Screw Jacks
Worm Gears
New Products

MR6

MS12

MR30

AG60

AG60+

ESA

 

Compacta AG60+ Gear Motor
Printable Documentation [pdf]

AG60+: General Specifications

Limit Switch Options

Dimensions mm (inches)

   

Dimensions mm (inches)

Options with dimensions [mm]
a(mm)
b(mm)
a(in)
b(in)
Single phase AC motor
(-)
(-)
(-)
(-)
DC motor
430
(-)
16.9
(-)
Motor disc brake
435
(-)
17.1
(-)
Hand crank
486
(-)
19.1
(-)
Limit switch version 1 / 3 / 2P / ESA
(-)
209
(-)
8.2
Single or double ended stub shaft
(x)
(x)
(x)
(x)
Mounting plate (torque support)
(x)
(x)
(x)
(x)
Mounting angle
(x)
(x)
(x)
(x)
Stainless steel hollow shaft 1.4104
(-)
(-)
(-)
(-)
(-) causes no size alteration
(x) Please refer to the datasheets for additional or missing dimensions.

3-phase AC motors - 3x230/460V-60Hz

Output speed
Output torque
Output torque
Transmission
Motor speed
Motor output
Motor output
Self
Max. limit switch range
RPM
Nm (60% duty cycle) ²
in-lbs (60% duty cycle) ²
ratio
RPM
kW
hp
locking
Output rotation ¹
15
650 (30%)
5752.9
223.0:1
3360
1.3
1.8
So
87
7.6
900
7965.6
446.0:1
3360
1.3
1.8
So
87
4.9
1350
11948.4
706.5:1
3360
1.3
1.8
So
87
3.5
1600
14161.1
967.0:1
3360
1.3
1.8
So
87
2.6
1600
14161.1
1264.0:1
3360
1.3
1.8
Ss
87
1.9
1600
14161.1
1785.0:1
3360
1.3
1.8
Ss
87
1.4
1600
14161.1
2343.0:1
3360
1.3
1.8
Sd
87
0.7
1600
14161.1
2343.0:1
1680
0.7
1.0
Sd
87

¹Please ask for max. limit switch range of ESA.
² At 100% duty (continuous duty), a cooling fan is required. With cooling, motors rated at 60% duty can be operated at 100% duty.
* 40% duty cycle.

So = no self locking;    Ss = static self locking;    Sd= dynamic self locking

Single phase AC motors - 1x230V-60Hz, 110V-60Hz

Output speed
Output torque
Output torque
Transmission
Motor speed
Motor output
Motor output
Self
Max. limit switch range
RPM
Nm (40% duty cycle) ²
In-lbs(40% duty cycle) ²
ratio
RPM
kW
hp
locking
Output rotation ¹
7.6
400
3540.3
446.0:1
3360
0.66
0.89
So
87
4.9
591.7
5236.7
706.5:1
3360
0.66
0.89
So
87
3.5
700.0
6195.5
967.0:1
3360
0.66
0.89
So
87
2.6
841.7
7449.3
1264.0:1
3360
0.66
0.89
Ss
87
1.9
966.7
8555.7
1785.0:1
3360
0.66
0.89
Ss
87
1.4
1133.3
10030.8
2343.0:1
3360
0.66
0.89
Sd
87
0.7
1229.2
10879.0
2343.0:1
1680
0.36
0.48
Sd
87

¹Please ask for max. limit switch range of ESA.
² The stated single phase torques are operational torques. The starting torque may be only 66% of the stated catalogue torqu
Please contact Concise Motion Systems in case maximum torque is required.

So = no self locking;    Ss = static self locking;    Sd= dynamic self locking

24V DC shunt wound motor

 
Output speed
Output torque
Output torque
Self locking
Transmission
 
RPM
Nm
in-lbs
 
ratio
 
4.4
525
4646.6
So
4467:1
 
2.8
765
6770.8
So
706.5:1
 
1.9
990
8762.2
So
967:1
 
1.6
1100
9735.8
So
1264:1
 
1.1
1265
11196.1
Ss
1785:1
 
0.8
1525
13497.3
Ss
2343:1

So = no self locking;    Ss = static self locking;    Sd= dynamic self locking

P = 0,45 kW, IN = 28A, 30% duty cycle
The output speed of Compacta gear motors with DC motors varies with the output torque.

Notes:

Load Capacity of the output shaft: Radial load - 2000N, Axial load - 1000N

The gear motor can be overloaded by 50% for brief periods. Single-phase AC- and DC motors may stall.

Please contact Concise Motion Systems in case of the following operating conditions:

  • Temperatures below 0°C (single phase AC and DC motors: below 10°C)
  • Temperatures above 40°C
  • Strong vibrations

 
 
 
 

General Terms & Conditions

 

Home Rotary Actuators