Concise Motion Systems
Home  | About Us  | Products  | Brands  | Applications  | Repairs  | Parts  | Contact Us  | Search    
 
innovative compact motion solutions
 
   
Linear Actuators
Rotary Actuators
Gearmotors
PushPull Chain
Screw Jacks
Worm Gears
Custom Drive Products for Solar Tracking
Precision Engineered Plastic Parts
New Products

MR6

MS12

MR30

AG60

AG60+

ESA

 

Compacta AG60+ Gear Motor by Framo Morat
Printable Documentation [pdf]

AG60+: General Specifications

Limit Switch Options

Dimensions mm (inches)

   

Dimensions mm (inches)

Options with dimensions [mm]
a(mm)
b(mm)
a(in)
b(in)
Single phase AC motor
(-)
(-)
(-)
(-)
DC motor
430
(-)
16.9
(-)
Motor disc brake
435
(-)
17.1
(-)
Hand crank
486
(-)
19.1
(-)
Limit switch version 1 / 3 / 2P / ESA
(-)
209
(-)
8.2
Single or double ended stub shaft
(x)
(x)
(x)
(x)
Mounting plate (torque support)
(x)
(x)
(x)
(x)
Mounting angle
(x)
(x)
(x)
(x)
Stainless steel hollow shaft 1.4104
(-)
(-)
(-)
(-)
(-) causes no size alteration
(x) Please refer to the datasheets for additional or missing dimensions.

3-phase AC motors - 3x230/460V-60Hz

Output speed
Output torque
Output torque
Transmission
Motor speed
Motor output
Motor output
Self
Max. limit switch range
RPM
Nm (60% duty cycle) ²
in-lbs (60% duty cycle) ²
ratio
RPM
kW
hp
locking
Output rotation ¹
15
650 (30%)
5752.9
223.0:1
3360
1.3
1.8
So
87
7.6
900
7965.6
446.0:1
3360
1.3
1.8
So
87
4.9
1350
11948.4
706.5:1
3360
1.3
1.8
So
87
3.5
1600
14161.1
967.0:1
3360
1.3
1.8
So
87
2.6
1600
14161.1
1264.0:1
3360
1.3
1.8
Ss
87
1.9
1600
14161.1
1785.0:1
3360
1.3
1.8
Ss
87
1.4
1600
14161.1
2343.0:1
3360
1.3
1.8
Sd
87
0.7
1600
14161.1
2343.0:1
1680
0.7
1.0
Sd
87

¹Please ask for max. limit switch range of ESA.
² At 100% duty (continuous duty), a cooling fan is required. With cooling, motors rated at 60% duty can be operated at 100% duty.
* 40% duty cycle.

So = no self locking;    Ss = static self locking;    Sd= dynamic self locking

Single phase AC motors - 1x230V-60Hz, 110V-60Hz

Output speed
Output torque
Output torque
Transmission
Motor speed
Motor output
Motor output
Self
Max. limit switch range
RPM
Nm (40% duty cycle) ²
In-lbs(40% duty cycle) ²
ratio
RPM
kW
hp
locking
Output rotation ¹
7.6
400
3540.3
446.0:1
3360
0.66
0.89
So
87
4.9
591.7
5236.7
706.5:1
3360
0.66
0.89
So
87
3.5
700.0
6195.5
967.0:1
3360
0.66
0.89
So
87
2.6
841.7
7449.3
1264.0:1
3360
0.66
0.89
Ss
87
1.9
966.7
8555.7
1785.0:1
3360
0.66
0.89
Ss
87
1.4
1133.3
10030.8
2343.0:1
3360
0.66
0.89
Sd
87
0.7
1229.2
10879.0
2343.0:1
1680
0.36
0.48
Sd
87

¹Please ask for max. limit switch range of ESA.
² The stated single phase torques are operational torques. The starting torque may be only 66% of the stated catalogue torqu
Please contact Concise Motion Systems in case maximum torque is required.

So = no self locking;    Ss = static self locking;    Sd= dynamic self locking

24V DC shunt wound motor

 
Output speed
Output torque
Output torque
Self locking
Transmission
 
RPM
Nm
in-lbs
 
ratio
 
4.4
525
4646.6
So
4467:1
 
2.8
765
6770.8
So
706.5:1
 
1.9
990
8762.2
So
967:1
 
1.6
1100
9735.8
So
1264:1
 
1.1
1265
11196.1
Ss
1785:1
 
0.8
1525
13497.3
Ss
2343:1

So = no self locking;    Ss = static self locking;    Sd= dynamic self locking

P = 0,45 kW, IN = 28A, 30% duty cycle
The output speed of Compacta gear motors with DC motors varies with the output torque.

Notes:

Load Capacity of the output shaft: Radial load - 2000N, Axial load - 1000N

The gear motor can be overloaded by 50% for brief periods. Single-phase AC- and DC motors may stall.

Please contact Concise Motion Systems in case of the following operating conditions:

  • Temperatures below 0°C (single phase AC and DC motors: below 10°C)
  • Temperatures above 40°C
  • Strong vibrations

 
 
 
 

General Terms & Conditions

Concise Motion Systems
Contact
Home